2. Test a. Open the front door of the camera and install the film pack simulator. The camera should not cycle. b. Remove the film pack simulator and install door pawl closure #12082. c. Install the film pack simulator again: - The camera should go through the dark slide cycle. - The shutter blades should remain closed. - The strobe should not charge (green LED off) - The counter should go from blank to #10. d. Depress the S10 Button lightly so that it just touches the S1 Button. - Four to six seconds later, the green LED should light, indicating strobe is charged. LED stays on about 30 seconds. - Depress S10/S1 Buttons fully: the strobe should fire. - Repeat step d. four more times. e. Cover the photocell with black photographic tape and turn the Camera to face you. - Depress the S1 Button only: the blades should open to a small aperture (f/20) and then close. - Repeat the step above four times. - Remove the tape from the photocell. f. Depress the Sl0/S1 buttons fully: - the camera will not cycle (Empty Pack Lockout). - the strobe will charge. - the green LED will light in 4 - 6 seconds. - the strobe will not fire. - the counter window will be blank.
g. Remove the film pack simulator and door pawl closure: - the counter will return to its starting position. h. Insert a known good film pack with film into the camera. Take a 2-foot cyan background picture with strobe: - observe that the film transport and delivery systems are functioning properly. - observe the finished picture for complete coverage. - observe the finished picture for evidence of dirt or cracks on the taking mirror.
TROUBLESHOOTING CHARTS (NOTE: Also see the RIB and Product Alert listing following these charts) PROBLEM | PROBABLE CAUSE | CORRECTIVE ACTION | Dark Slide Cycle with Front Door Open (Non-Continuous) (If cycling continuously go to Continuous Cycling chart) | 1. Door pawl spring defective or not loaded under pack pawl. 2.S1 slider fingers and switches on contact support block not interfaced properly. | 1. Replace spring or load spring properly. 2. Disassemble and install properly | | 3. S1 switch contacts deformed. (Closed with front door open - check with meter). | 3. Re-form S1 contacts if possible. Replace contact support block if necessary. | | 4. Contact support block defective. | 4. Replace contact support block. | No Dark Slide Cycle | 1. S9 switch open (check with meter). support block if necessary. | 1. Re-form S-9 switch contacts. Replace | | 2. S1 slider fingers and switches on contact support block not interfaced properly. | 2. Disassemble and install properly. | | 3. S1 slider cam not mated to counter properly. | 3. Disassemble and install properly. | | 4. S1 switch contacts deformed (closed with front door open - check with meter). | 4. Re-form S1 contacts if possible. Replace contact support block if necessary. | | 5. Contact support block defective. | 5. Replace contact support block. | | 6. Battery (+) wire not trapped in contact support block properly. | 6. Install battery wire properly. | | 7. Flex circuit motor contacts not seated properly. | 7. Install flex motor contacts properly. | | 8. Counter spring defective or not loaded properly. | 8. Repair or replace spring. |
|